Showing results: 91 - 105 of 158 items found.
-
Mors Smitt Group
The transducers are based on compensating the magnetic field by a closed loop system. Ensure high accuracy of voltage and current measuring in railway traction or substation power equipment for protetion against power surges, overload, ground fault detection. Hall effect measurement to offer maximum protection in railway applications.
-
RCTi and RCTi 3ph -
Powertek LLC
The RCTi & RCTrms sensors convert ac current to an isolated 0-5V voltage or 4-20mA current loop. TA5V-5A allows compatibility with existing 1A or 5A CT metering circuits. Both offer a choice of proportional (rms) and instantaneous outputs. The available RCT current ranges are 0-100A to 0-50,000Apk. Both RCTi and RCTrms provide accurate measurement over a wide bandwidth ensuring precise measurement even with harmonically distorted wave shapes - using a flexible clip-on sensing coil. The RCTs are available as single and three phase models.
-
Extech 412400 -
Extech Instruments Corporation
The Extech 412400 Multifunction Process Calibrator sources and measures thermocouples (J, K, and T), mA, mV, and V devices. The 24 V loop supply drives current loads up to 1000 ohms. It has memory for 5 user-settable output values of each type for fast calibrations. Single and continuous step function for voltage and current. Comes complete with six AA batteries and a calibration cable with spade lug terminals.
-
APCI-7300-3 -
TEAM SOLUTIONS, INC.
*PCI interface to the 32-bit data bus. *Asynchronous communication adapter, 1-port serial interface*1 socket for SI modules*Modular structure through SI modules*Configurable as: RS232, RS422, RS485, with or without isolation, or 20 mA Current Loop (active, passive) with isolation*Addressing through software
-
8012eS -
Sealevel Systems, Inc.
The 8012eS PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
72-7730A -
Tenma
Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.
-
APCI-7420-3 -
TEAM SOLUTIONS, INC.
*RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without optical isolation*Modular structure through MX-modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer common interrupt*Automatic direction recognition for RS485*Transmission mode: asynchronous, full, half duplex
-
8012e -
Sealevel Systems, Inc.
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
T4111 -
COMET SYSTEM, s.r.o.
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.
-
VX4620 -
VX Instruments GmbH
Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability
-
1625-2 -
Fluke Corporation
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.
-
1826 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
DGH Corporation
USB analog and digital I/O modules are a complete family of data acquisition modules for use in process control systems. The analog input modules can measure process signals such as DC voltage, thermocouples, 4-20mA current loops, discrete contact closures.
-
CPCI-7500 -
TEAM SOLUTIONS, INC.
*This Model has a 37-pin D-Sub male connector*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)*Transmission mode asynchronous, full, half duplex*Transfer rate: progr. up to 115.2 kBaud up to 1 MBaud on request*Protocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bits*Parity: even, odd, none, mark or space*Interrupt lines: automatic through BIOS
-
8004 -
Sealevel Systems, Inc.
The 8004 PCI digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide high quality, long-life, low-current (10 Watt maximum), dry contact switch closures.